MCT4 Multi-Loop Touch Screen Controller 1/4 DIN
     Products > > FDC-IO Modules

Data Acquisition and Distributed FDC-IO Modules
Data Acquisition Distributed IO Modules               
Applications:
 
Features:
  • Data Acquisition
  • Remote IO
  •  
  • Serial Modbus RTU RS485
  • Analog Input T/C, RDT, mA & VDC Modules
  • Combination Digital Input & Output Modules
  • Digital Input Modules
  • Digital Output Modules
  •   CE   Rohs

     

    FDC-IO Additional Page Links

    Overview of FDC-IO Module System

     

    Product Brochure, Manual & Pricing

    FDC-IO_Brochure_v1.1_04-06-2020.pdf [70KB]

    FDC-IO_Manual_v1.1_September-2009.pdf [1.1MB]

    FDC-IO_Price.pdf[36KB]

     

    Additional Information

    -

    IO Studio Configuration Software

    FDC-IO Studio_v2.8_Configuration_Software.zip

    FDC-IO_Studio_v-UMIOE_Manual.pdf

     

    FDC-IO Studio Data Acquisition Studio Software & Manual

    FDC-IO Data Acquisition Studio DAQ v2.30.zip [59MB]

    FDC_IO_DAQ Studio_Manual_UMDAQC.pdf [4MB]

    FDC IO DAQ Studio DEMOA.zip [47MB]

    -

    FDC-IO Overview

    Overview of FDC-IO Module System.htm

    -

    Power Point Sales Presentation & Feature Review

    FDC-IO_PC-E_Sales_Presentation_ppt.zip [4.5MB]

    -

    Power Supply - 24VDC Output

    PS5R-SD Power Supply.pdf [290KB]

    -

    Serial Modbus to Ethernet Gateway Converter

    FDC-PC_E_Gateway.html

     

    Field Bus Converter - Serial to DeviceNet, Profibus-DP, CANopen, etc.

    Orion-M_Anybus Gateways.html

    -

    Wireless Transmitter: Serial and/or Ethernet

    PC-W_Gateway.html

    -

    RS232 to 485 Converters - Gateways

    RS232/485 SN10A Converter for PC communication.pdf

    -

    CE - RoHS Conformity Information

    CE Conformity.pdf

    EU_REACH Compliance.pdf

    RoHS-3 Compliance.pdf


    Need single loop controls and Data Acquisition system?

    Orion-M iSeries & nCompass LC, MC & CM Operator Interface & Data Acquisition Systems for100/C, 300, B41 and B42, L, & P Series Controls and FDC IO modules

    nCompass LC control

    nCompass Single & Multiloop Control Systems

    Windows CE embedded Operator Interface and Data Acquisition offering 4.3" & 7" touch screen displays supporting up to 10 loop controls, up to 15 monitor points with up to 16 DI and 32 DO for user configurable control outputs, sequencing & logic.

    Go to nCompass Page.htm

     

    Orion-M iSeries Multiloop Control System

    Windows CE embedded Operator Interface and Data Acquisition offering 7" & 10" touch screen displays supporting up to 15 loop controls, 15 monitor points with up to 16 DI and 32 DO for user configurable control outputs, sequencing & logic.

    Go to Orion-M iSeries Page.htm

     

    EnVision PC Based Data Acquisition

    A FREE PC based SCADA software offers unrivaled flexibility for remote SCADA access to up to a mix of 128 devices.

     

    Devices include Future Design Controls loop, IO and Orion-M iSeries control systems.

    Go to EnVision Page.htm

     

    Return To:

    Additional features for Profile Control.htm

    Process & Temperature Control Page.htm

     

     

    High Resolution Modbus RTU Protocol IO Modules
    for PLC, HMI, SCADA, etc.

    The FDC-IO Modules offer Analog & Digital IO modules (Modbus RTU slave) for data acquisition and other applications offering reliable low-cost solution for distributed IO applications to PLC’s, HMI’s and/or PC based SCADA systems. All modules have LED indicators for visualization of IO status (digital), fault diagnostic analysis and easy DIP Switch configuration for Modbus addressing from 1 to 127.

    PC based configuration software, IO Studio, is provided and used for module configuration, viewing real time data and when necessary to check IO status. Module Modbus address is configured by DIP Switch.

    The optional IO Studio DAQ ( Data Acquisition) software provides the same features as the IO Studio configuration software but also Real time viewing & data acquisition of RTU/Modbus TCP slave devices like the FDC-IO Modules. The software shows real-time data in the form of digital values, bar graphs, trends, etc. as well as a Historical Data Viewer with a maximum of 1024 tags. The IO Studio DAQ software carries a modest sell price (less then $200) it will run in demo mode for one hour and a demo only version may be downloaded here; IO Studio DEMOA.

    Download the IO Studio DAQ software here with a demo mode that is good for one hour of use. Purchase of the software provides a Hardware lock (Key Pro) that plugs into the host PC's USB port. For detailed information download the FDC_IO_Studio_DAQ_Manual_UMDAQC.pdf

    For Additional information - Overview of FDC-IO Module System

    FREE EnVision PC Based SCADA Software

    EnVision, a FREE PC based SCADA software offers unrivaled flexibility for remote SCADA access to up to a mix of 128 devices including loop controls, 8-channel analog input modules and Orion-M iSeries control systems.

    • Data Logging: Each of the 128 devices, whether a mix of IO Modules or other Future Design products, can have their data saved to the hard disk at user-defined rates. With up to 129 concurrent data log files, EnVision offers unparalleled data logging flexibility. Data file analysis tools (digital and trend) make looking at schedule run data a simple task

    Connect IO Modules via Ethernet? The PC-E Serial Modbus to Modbus TCP Ethernet converter provides an easy & cost effective manner to connect Serial Modbus devices to Ethernet TCP networks; for additional information refer to PC-E sales brochure.

    FDC-IO Modules Model Numbers & Description of Features

    Digital Input & Output Modules

    • Digital Input Modules:
      • IO-16DI: 16 digital inputs & counters
    • Digital Output Modules
      • IO-16DO: 16 digital output (24 VDC)
      • IO-4RO: 4-relay output (form C)
    • Digital Input & Output combination Modules
      • IO-8DIO: 8 digital input & 8 digital outputs (24 VDC)

    Analog Input & Output Modules

    • Analog Input Modules: Thermocouple & RTD
      • Applicable to both T/C & RTD units: value read in Modbus register is the actual temperature value (0.1C); i.e. value of 3451 = 345.1C
      • IO-8TCS: 8 Inputs, Thermocouple, 0-50mV and 0-100mV
        • Accuracy typical 0.3C / CJC 0.5C
        • Resolution 0.1C
        • Sample Rate .71 / second
        • Channel to channel isolation
      • IO-6RTD: 6 RTD Inputs
        • PT100/1000, NI120/100
        • Accuracy 0.3C
        • Resolution 0.1C
        • Sample Rate .52 / second
    • Analog Input Modules: mA and VDC (12-bit/Accuracy 0.2%)
      • IO-AIIS: 8 Analog mA Input (0-20 / 4-20mA)
        • Channel to channel isolation
      • IO-AIVS: 8 Analog VDC Input (0-5/1-5/0-10/2-10VDC)
        • Channel to channel isolation
      • Sample Rate all Models: 12.5 samples per second
    • Analog Output Modules: (12-bit / Accuracy 0.05%)
      • IO-AOI: 8 Analog mA Output (0-20 or 4-20mA)
      • IO-AOV: 8 Analog VDC Output (0-10 or 2-10VDC)

    Combined Analog Input & Digital I/O Modules

    •  Digital Input & Output combination Modules
      • IO-8DIO:
        • 8 digital input & 8 digital outputs (24 VDC)
        • Analog: quantity 2 mA/VDC and 2 RTD
    •  Combination Input/Output Module:
      • IO-DAIO
        • Analog Input: Quantity 2 RTD and 2 Analog inputs
          • (mA/VDC - jumper configurable)
        • Analog Output: quantity 1
          • (mA/VDC - jumper configurable)
        • Digital Inputs: quantity 4 DI (24VDC)
        • Digital Outputs: quantity 2 DO (24VDC)

     

    ______________________________________________

     

     

    Return to Top of Page

     

    Return To:

    Main Products Page

     

    Join Our Mailing List
    Email:

    Customer Service: 888-751-5444 / csr@futuredesigncontrols.com

    Technical Support: 866-342-5332 / support@futuredesigncontrols.com

     

    Return to:

    Main Products Page.htm

     

     
    Future Design Controls   888.751.5444   csr@futuredesigncontrols.com